ThomasNet
Five Penn Plaza
New York
NY 10001, USA
Phone: (212) 290 7390
Fax: (212) 290 7390

E-mail:
salesengineers@thomasnet.com

 

All Categories1 > Heaters > Antenna & Cable Testing > Power Sensors > Item # 5010B  


Item # 5010B, Digital Power Sensor


selection
  • Dual-element THRULINE® design for simultaneous forward and reflected power readings.
  • Measures true average power.
  • Peak power measurement (using 43 elements)
  • ± 5% of reading accuracy rivals thermal wattmeters in actual field use.
  • Small, easily-remoted sensor facilitates convenient hand-held operation.




 Specifications 

Required Products

The Bird® Model 5000-EX or the Bird® Site Analyzer® Series (SA-6000EX, SA-4000EX, SA-2500EX, or SA-1700EXP)

Sensor Type

Bird® THRULINE® directional dual-element line section

Frequency Range

Element limited

Power Range

Element limited

Pulse width Parameters

>100 MHz 800 ns min.; 26-99 MHz 1.5 µs min.; 2-25 MHz 15 µs min.

Pulse Rep. Rate Peak

15 pps min.

Pulse Duty Factor

1 x 104min.

Accuracy

True Average Power, ± 5% of reading (15 to 35°C), ± 7% of reading (-10 to 50°C) Peak Power, ± 8% of full scale

Dynamic Range

40:1 (E.G.50 W element measure 1.25 W to 50 W).

Peak/Average Ratio

10 dB maximum with DPM elements

Settling Time

< 2 seconds

Connectors

QC Type. Female N normally supplied.

Insertion VSWR

1.05:1 from 0.45 to 1000 MHz (with N connectors)

Size [inches (mm)]

1.875 inch H x 1.875 inch W x 3.5 inch D (47.7 mm x 47.7 mm x 88.9 mm) excluding connectors

Weight

1.12 lbs (0.51 kg)

Operating Temperature [°C (°F)]

-10 to +50

Storage Temperature [°C (°F)]

-40 to +75

Humidity, Max.

95% max. (non-condensing)

Note

5010B supercedes 5010



Print Back