Registered Users
–
Sign In
Search Catalog
By Keyword
By Item #
By UNSPSC Number
All Categories1
Flanged Immersion Heaters
Valves, Nuts and Bolts
|
Shipping
|
Tax
|
Terms
Shopping Cart
0 Items
Request for Quote
0 Items
All Categories1
>
Heaters
>
Immersion Heaters
>
Flanged Immersion Heaters
>
Item # 3L3-22-3
larger image
Item # 3L3-22-3, Flanged Immersion Heaters
List Price $15,435.00
(
Quantity Discount
Available )
Flange Immersion Heaters with a watt density of 13 W/sq in. are suited for medium weight oils, #4 & #5 fuel oils, corrosives, air, and gases. They feature 334 stainless steel sheath for the widest coverage of applications and temperatures, #10-32 terminals for wiring connections, NEMA 1 housing, and 150 lb. rated flanges with ASA drill pattern.
Specifications
·
Applications
·
Standard Features
·
Optional / Additional Features
Specifications
Watt Density (Watts/in
2
)
13
Application
Medium Wt. Oils, #'s 4 & 5 Fuel Oils, Corrosives, Air & Gases
Immersed Length (inches)
25.25
Flange Size (inches)
3
Volts
240
Kilowatts
2.25
Number of Circuits
1
Shipping Weight (pounds)
17
The following options are available
for this product.
Select "Request Information" or "Add To Cart" to make your selections.
Terminal Housing Options
NEMA 1 (standard)
NEMA 4- Moisture Resistant
($165.00)
NEMA 7- Explosion Resistant
($216.00)
Flange Options
150# Steel Flange (standard)
300# Steel Flange
($74.00)
150# 304 St. Steel
($416.00)
300# 304 St. Steel
($839.00)
Gasket Options
Standard Gasket
150# Asbestos
($7.00)
150# Flexitallic
($22.00)
300# Asbestos
($9.00)
300# Flexitallic
($26.00)
Double Pole Thermostat Options
No Thermostat
T4 (0-1000 ° F) in NEMA 1 Housing
($384.00)
T5 (60-250 ° F) in NEMA 1 Housing
($384.00)
T6 (150-550 ° F) in NEMA 1 Housing
($384.00)
T4 (0-1000 ° F) in NEMA 4 Housing
($407.00)
T5 (60-250 ° F) in NEMA 4 Housing
($407.00)
T6 (150-550 ° F) in NEMA 4 Housing
($407.00)
T4 (0-1000 ° F) in NEMA 7 Housing
($407.00)
T5 (60-250 ° F) in NEMA 7 Housing
($407.00)
T6 (150-550 ° F) in NEMA 7 Housing
($407.00)
Thermocouple Options
No Thermocouple (standard)
Type J or K to sheath
($305.00)
Type J or K free
($169.00)
Applications
Flanged immersion heaters are versatile in heating oil, heat transfer oils, water, gases, and other liquid solutions. These heaters may be used in pressure vessels and various process tanks, being directly immersed for optimum performance. Resources are available to provide a suitable flange heater not only for those applications stated, but also for those that require special materials such as Inconel 600, Monel 400, Hastelloy, titanium, and 300 series stainless steels. We have HOT IDEAS for your particular application!
Standard Features
UL & CSA recognition on elements.
334 stainless steel sheath (equivalent to Incoloy 840) standard for most applications and temperatures.
Type 'A' 80/20 resistance wire sized to provide low wire watt density for maximum life.
Fusion welded junction between pin and resistance wire for superior strength.
High purity MgO compacted to provide maximum heat conductivity and optimum dielectric integrity.
Recompacted bends on hairpin end of elements to restore MgO density.
Terminal ends moisture sealed against the entrance of contaminants during storage and service.
#10-32 terminals with screw lug line connectors.
Welded construction between elements and flanges; silver braze construction on non ferrous materials.
ALL joints between elements and flange pressure tested for leaks.
Spacer supports on units where immersed length exceeds 18".
NEMA 1 housings; seamless and deep drawn on 8" and under flanges to provide accessibility to wiring, plus afford a degree of protection against splashing or dripping liquids.
1/2" O.D. thermowell for existing or optional thermostat.
100% inspected for:
Dielectric or Hi-Pot between conductors and sheath of element.
Insulation resistance.
Wattage
Optional / Additional Features
ASME Section VIII , Div. 1, design and code stamp available.
NEMA 4 moisture or NEMA 7 explosion resistant enclosures available on all flange sizes.
Standoff housing design for high temperature applications.
DPST thermostat controls available in three temperature ranges, inside NEMA 1, 4, or 7 housings.
MgO filled type J or K thermocouples for control or high limit protection.
NOTE: Hi-limit thermocouples welded to element sheath provides positive sensing protection for over heat situations. Thermocouple junction should be at area of highest operating temperature.
Various selection of sheath materials... Monel 400, Inconel 600, Hastelloy, Carpenter 20, and Titanium.
Type 304 or 316 stainless steel flanges.
Passivation or Electropolishing on elements and flanges for pure and deionized water, photo chemicals and special processes.
Baffle assembly between elements to direct flow in vessel applications.
Special lengths, wattage's and voltages... consult factory.
Solid state digital controls available for thermocouple inputs.
Download PDF
Download PDF
Printable Page
Email This Page
Save To Favorites
Please wait…
MORE IMAGES
·
Construction Notes and Options
·
Flange Dimensions